10. connecting input power – Miller Electric 225 User Manual

Page 23

Advertising
background image

OM-316 Page 19

4-10. Connecting Input Power

Ref. 802 246

For Models Supplied With Plug
Y Disconnect and lockout/tag-

out input power before instal-

ling receptacle.

Y Have only qualified persons

make this installation. See

rating label in Section 4-4, and

be sure to supply correct in-

put power.

1

Proper Receptacle

(User-Supplied)

Receptacle must comply with appli-

cable codes.
2

Input And Grounding

Conductors

See size and length using Section

4-7. Conductors must comply with

applicable codes.
3

Over-Current Protection

Select type and size of over-current

protection using Section 4-7.
4

Plug

Connect plug to properly installed

receptacle.

4

1

3

L1

3

L2

For Models Not Supplied With Plug
Y Installation must meet all National and

Local Codes − have only qualified per-

sons make this installation.

Y Disconnect and lockout/tagout input

power before connecting input con-

ductors from unit.

Y Always connect green or green/yellow

conductor to supply grounding termi-

nal first, and never to a line terminal.

1

Line Disconnect Device (Switch Shown

In Off Position)

2

Disconnect Device Grounding Terminal

3

Green Or Green/Yellow Grounding

Conductor

Connect green or green/yellow grounding

conductor to disconnect device grounding ter-

minal first.
4

Disconnect Device Line Terminals

5

Black And White Input Conductors L1

And L2

Connect input conductors L1 and L2 to dis-

connect device line terminals.
6

Over-Current Protection

Select type and size of over-current protection

using Section 4-7 (fused disconnect switch

shown).
Close and secure door on disconnect device.

Remove lockout/tagout device, and place

switch in the On position.

Or

2

=GND/PE Earth Ground

1

1

2

4

5

6

1