ELECTRICAL WIRING (MILLI-VOLT)

The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO OPER-
ATE.

CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT

1. Use 18 awg, two-wire cable, 15 feet maximum length.
2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to

TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of
the unit. The color of the wires does not matter.

Figure 17 - Wiring Diagram

Note: Log switch wires are not factory connected.

Connect log switch wires to the TH/TP and TH valve terminals as shown.

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation. Verify
proper operation after servicing.

Log Switch

On/Off

Switch or

Optional

Wall

Switch,

Remote or

T-Stat

ODS

Pilot

Milli-volt

Valve

TH = 3

TP = 1

TP/TH = 2

ODS

Pilot