6

70D0004

PRODUCT FEATURES

AND

SPECIFICATIONS

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 10

1

/

2

" W.C. on

natural gas systems operating at higher pressure.

MILLI-VOLT

Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator:

3.5" w.c.

Gas Inlet Pressure:

Max 10

1

/

2

" w.c.

Min. 5" w.c.

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

MILLI-VOLT

Regulator Pressure Setting: 10" w.c
Gas Inlet Pressure:

Max. 13" w.c.

Min. 11" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.

Milli-Volt control has four (4) positions:

OFF

- All gas to the gas logs is shut off at the valve.

IGN

- Valve position to light/maintain a standing pilot.

ON

- Valve position to turn ON/OFF log set with remote switch/thermostat.

LOW/HI

- Variable position to control flame height (heat output).

PILOT/ODS

The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a milli-volt (thermopile) generator to provide power for remote activation.

Model Number

Control

Gas Rate

Max BTU/Hr

Min BTU/Hr

TPB18NV

Milli-Volt

28,000

19,000

TPB24NV

Milli-Volt

38,000

26,000

TPB30NV

Milli-Volt

38,000

26,000

Model Number

Control

Gas Rate

Max BTU/Hr

Min BTU/Hr

TPB18PV

Milli-Volt

28,000

23,000

TPB24PV

Milli-Volt

34,000

26,000

TPB30PV

Milli-Volt

34,000

26,000