FIREPLACE AND HEARTH DIMENSIONS

Use manufacturer's installation and clearance requirements as defi ned in their manual.

The TPB Series unvented room heater is approved for installation into the following unvented fireplaces:

GCUF Series Fireboxes Magnum36/42, Lo-Rider36

or BUF

The TPB Series unvented room heater may also be installed into a Ventless Firebox Enclosure for Gas Fired Decorative

Type Unvented Room Heaters per IAS Requirement No. 2-97 ANSI Z21.91-2001 (typically referred to as a "Universal

Firebox"), as long as firebox hearth dimensions meet the minimum hearth dimensions shown below.

Figure 2 - Hearth Minimum Dimension

This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-
built fi replace, vent free appliance, or in listed ventless fi rebox enclosure. It has been
design certifi ed for these installations.

Exception: DO NOT install this appliance in a factory-built fi replace that includes
instructions stating it has not been tested or should not be used with unvented gas
logs.

W

ARNING

Model

A

B*

C

D

TPB18

26"

13"

18"

17"

TPB24

29"

13"

22

1

/

4

"

17"

TPB30

33"

13"

25

1

/

4

"

17"

* Without front grate installed "B" will be 12 ½.