NPort 5400 Series User’s Manual

Web Console Configuration

5-10

Port alias

Setting

Factory Default

Necessity

1 to 15 characters
(E.g., PLC-No.1)

None Optional

Port Alias is specially designed to allow easy identification of the serial devices which are
connected to NPort’s serial port.

Serial Parameters

ATTENTION

Check the serial communication parameters in your Serial Device’s user’s manual. You should
set up NPort’s serial parameters with the same communication parameters used by your serial
devices.

Baud rate

Setting

Factory Default

Necessity

50 bps to 921600 bps

115200 bps

Required

NPort supports baud rate setting from 50 bps to 921.6 Kbps.

Data bits

Setting

Factory Default

Necessity

5, 6, 7, 8

8

Required

When the user sets Data bits to 5 bits, the stop bits setting will automatically change to 1.5 bits.

Stop bits

Setting

Factory Default

Necessity

1, 2

1

Required

Stop bits will be set to 1.5 when Data bits is set to 5 bits.

Parity

Setting

Factory Default

Necessity

None, Even, Odd, Space, Mark

None

Required

Flow control

Setting

Factory Default

Necessity

None, RTS/CTS, DTR/DSR, Xon/Xoff

RTS/CTS

Required

FIFO

Setting

Factory Default

Necessity

Enable, Disable

Enable

Required

NPort’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. Disable the FIFO
setting when your serial device does not have a FIFO to prevent data loss during communication.