Mustang Survival MD3082 User Manual

Page 13

Advertising
background image

Tab

Piercing Pin

Cylinder

Lever

Service Indicator

MD3081 and MD3082 Manual Inflator

1/8 Turn

Cylinder

1/8 Turn

Tab

Piercing Pin

Lever

Service

Indicator

MD3081 and MD3082 Manual Inflator

FIGURE 9

5) Examine the service indicator (Fig. 9) and ensure it is GREEN. If

the service indicator is red, the mechanism has been fired or is
incorrectly fitted and the inflator requires service. See Re-arming Your
PFD (MD3081 and MD3082) p. 8.
NOTE: The service indicator must be green before proceeding.

6) Refold the Inflatable PFD in accordance with the Repacking section

(p. 13).

YOUR INFLATABLE PFD (MD3081 and MD3082) IS NOW READY FOR
MANUAL USE

Re-arming Your PFD (MD3083 and MD3084)

NOTE: A re-arm kit (MA7202) with a valid bobbin install-by-date
(check re-arm kit packaging) is required for this procedure.

IMPORTANT: Follow instructions in the exact sequence below.

1) Unpack or open the Inflatable PFD so that the manual/automatic

inflator is exposed (Fig. 10).

2) Remove the cylinder/bayonet assembly by rotating counter-clockwise

and then pull out. Discard the used cylinder/bayonet assembly.
NOTE: You will damage the sensor ring if the bobbin and cap
are not installed first.

3) Remove cap by turning counter-clockwise. (Fig. 10).
4) Remove bobbin from cap or housing unit. Discard bobbin.

NOTE: The yellow bobbin may remain in the housing or in the
cap assembly when you remove the cap. The bobbin must be

Inflatable PFD Owner’s Manual