For use of optional ak-4 outside air kit – Monessen Hearth BUF400 User Manual

Page 16

Advertising
background image

16

61D1013

8'max.

FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT

COMBUSTION AIR

1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any

manner. Locate assembly a min. of 12" above the snow line to prevent blockage by snow accumulation.

2. Never mount the combustion air inlet assembly in a garage or storage area where combustible fumes such

as gasoline might be drawn into the fireplace.

3. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is provided

by open ventilation.

4. CAUTION: Do not take combustion air from attic space or garage space.
5. Locate air supply inlet at least 3' away from any appliance vent terminal.
6. Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air

assembly. These conditions increase the resistance to the free flow of air through the duct. See Figures 14
through 17
for methods of installing the outside air for combustion assemblies.

Figure 14 - Basement Installation

Figure 15 - Concrete Slab Installation

(Optional Outside Air Runs)

Above

Snow

Level

Ground

Level

Basement
Wall

Inlet Grill in

Soffit

(Overhang)

Figure 17 - 45° Corner Installation on

Slab Floor

Figure 16 - Installation Above Basement or

Crawl Space

Inside Wall

Outside

Wall

Duct Extended

to Miss Joist

To Outside Wall

Note: Fireplace model in illustrations may not be representative of your appliance.