Monessen Hearth BUF400 User Manual

Page 7

Advertising
background image

61D1013

7

17"

21

1

/

2

"

BUF400: 35

1

/

2

"

BUF400: 20

3

/

8

"

BUF500: 26

3

/

8

"

BUF500: 41

1

/

2

"

Figure 3 - Location of Firebox

MINIMUM HEARTH DIMENSIONS

GENERAL INSTALLATION INFORMATION

Figure 2 - Minimum Hearth Dimensions

Carefully select the best location for installation of your
vent-free firebox. The following factors should be taken
into consideration:
• Clearance to side wall, ceiling, woodwork and windows.

See “Clearances/Height Requirements on page 8.
Minimum clearances to combustibles must be main-
tained.

• Location must not be affected by drafts caused by

kitchen exhaust fans, ceiling fans, return air registers
for forced air furnaces / air conditioners, windows or
doors.

• Installation must provide adequate ventilation and

combustion air.

DO NOT INSTALL THIS FIREBOX IN A BEDROOM

OR BATHROOM.

• Location should be out of high traffic or windy or drafty

areas.

DO NOT INSTALL WHERE CURTAINS, FURNITURE, CLOTHING OR OTHER FLAMMABLE OBJECTS

ARE LESS THAN 42" FROM FRONT OF HEATER.

• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation

air.

• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox

must be kept clear and free from these combustible materials.

LOCATION OF FIREBOX