1. specifications, 2. duty cycle and overheating – Miller Electric Regency 250 User Manual

Page 13

Advertising
background image

OM-293 Page 9

SECTION 2 – INSTALLATION

2-1.

Specifications

Rated Welding

Voltage Range

Maximum Open-

Amperes Input at Rated Load

Output, 60 Hz, Single-Phase

Output

DC

Circuit Voltage DC

200 V

230 V

460 V

KVA

KW

200 A @ 28 Volts DC,

60% Duty Cycle

Low Range: 10–20

V; High Range:

20–30 V

42

46

(1.2*)

40

(1.0*)

20

(0.5*)

9.2

(0.2*)

8.3

(0.1*)

*While idling

2-2.

Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.

If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.

Y

Exceeding duty cycle can
damage unit and void war-
ranty.

Overheating

0

15

A or V

OR

Reduce Duty Cycle

Minutes

sduty1 5/95 / 155 647-A

60% Duty Cycle At 200 Amperes

6 Minutes Welding

4 Minutes Resting

Advertising