5. dimensions and weights, 6. weld output terminals and selecting cable sizes – Miller Electric Regency 250 User Manual

Page 15

Advertising
background image

OM-293 Page 11

2-5.

Dimensions And Weights

Dimensions

Height

23-1/4 in (591 mm)

C

H 8 Holes

Width

16 in (406 mm)

Depth

22-3/4 in (578 mm)

A

13 in (330 mm)

A

B

12-1/4 in (311 mm)

B

C

3/4 in (19 mm)

Front

D

16-1/16 in (408 mm)

E

14-29/32 in (379 mm)

F

15-13/32 in (137 mm)

G

G

13/32 in (10 mm)

E

F

H

7/16 (11 mm) Dia

155 897-A

D

Weight

168 lb (76 kg)

2-6.

Weld Output Terminals And Selecting Cable Sizes

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Weld Output

Terminals

Welding

Amperes

10 – 60%

Duty

Cycle

60 – 100%

Duty

Cycle

10 – 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

Negative

(–)

Positive

(+)

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

Ref. 121 470-E

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.