11a-9-6 – Mitsubishi Motors 4G9 User Manual

Page 133

Advertising
background image

www.mivec.co.nz

4G9 ENGINE (E - W) -

Cylinder Head and Valves

11A-9-6

PWEE9502-A

E

Nov. 1995

Mitsubishi Motors Corporation

Revised

Caution

D

Valves must be neutralized one at a time.

D

Put a valve in the container only after sodium
in the preceding one has completely reacted with
water.

Keep fire away from the container during the

neutralization. The resulting hydrogen gas is highly

explosive.

When the reaction has finished (there is no more

generation of hydrogen gas), take the valves out of the

container with large tweezers or the like.

NOTE

The reaction occurs when water enters the cavity in the

valve. Hydrogen gas may be trapped inside the valve,

temporarily blocking the water passage. In such a case,

wait until hydrogen gas in released and remaining sodium

reacts with water.

After the neutralization of sodium, water in the container

contains sodium hydroxide and is highly alkaline. The

water solution should be disposed of according to local

regulations.

Caution

D

Do not let the solution contact the eyes or the
skin.

D

Should it get in the eyes, immediately flush them
with clean water thoroughly, and receive medical
attention. When it contacts the skin, wash with
ample amounts of clean water.

INSTALLATION SERVICE POINTS

"

A

A

VALVE STEM SEAL INSTALLATION

(1) Install the vale spring seat.

(2) Use the special tool to install the valve stem seal. Improper

installation could result oil leaking past the valve guide.

Caution
Do not reuse removed valve stem seals.

SOHC

MD998774

DOHC

MD998775

Advertising