Design specifications – Metrologic Instruments IS8000 Series User Manual

Page 25

Advertising
background image

21

A

PPENDIX

A (

CONTINUED

)

Design Specifications

I S 8 8 0 0

I S 8 5 0 0

I S 8 4 0 0

I S 8 3 0 0

E l e c t r i c a l

Input Voltage

12 VDC

12 VDC

12 VDC

12 VDC

Starting Power

69 watts

69 watts

53 watts

53 watts

Operating power

43 watts

43 watts

34 watts

34 watts

EMC: FCC, ICES-003 &
EN 55022

Class A

Class A

Class A

Class A

L a s e r

Wavelength

658 nm ± 5 nm

658 nm ± 5 nm

658 nm ± 5 nm

658 nm ± 5 nm

Laser power (peak)

7.7 mW

7.7 mW

7.7 mW

7.7 mW

Laser power (average)

<1 mW

<1 mW

<1 mW

<1 mW

Laser class: CDRH

Class II

Class II

Class II

Class II

Laser class: EN

Class 2

Class 2

Class 2

Class 2

E n v i r o n m e n t a l

Operating Temperature

0°C to 40°C (32°F to 104°F)

Storage Temperature

-40°C to 60°C (-40°F to 140°F)

Humidity

5% to 95% relative humidity, non-condensing

Light Levels

Up to 297.4 lux (3200 foot candles) – works in direct sunlight

Shock

100 g for 1 ms

Contaminants

Protects against dust, falling dirt, and dripping non-corrosive liquid

Ventilation

None required

Actual scan areas will vary by label size and application.

Specifications subject to change without notice.