3

I

NSTALLING THE

S

CANNER TO THE

H

OST

(S

TANDARD

F

EATURES

)

Single HoloTrak

®

Installation

To avoid potential problems, do not power up the scanner until the
communication cable is secured to the host.

1. Turn off the host system.

2. Connect the communications

cable to the HoloTrak

®

and

to the host.

3. Check the AC input

requirements of the power
supply to make sure the
voltage matches the AC
outlet.

4. Plug the power supply to

the scanner.

5. Plug the power supply into

the AC outlet to supply
power to the scanner.

6. Power up the host system.

HoloTrak Primary/Secondary Feature

The primary/secondary feature gives the ability to connect or "daisy-chain" two
scanners together to act as one scanner interfacing with only one host.

P

RIMARY

/S

ECONDARY

C

OVERAGE WITH

O

NE

H

OST AND

T

WO

H

OLO

T

RAKS

Single Conveyor

Two Conveyors

IS8300

12” (305 mm) to 24” (610 mm)

12” (305 mm) coverage per conveyor

IS8400

22" (559 mm) to 44" (1118 mm)

22” (559 mm) coverage per conveyor

IS8500

22" (559 mm) to 44" (1118 mm)

22” (559 mm) coverage per conveyor

IS8800

18” (457 mm) to 36” (914 mm)

18” (457 mm) coverage per conveyor

Continued on next page

Caution:

To maintain compliance with applicable standards, all circuits connected to the scanner must meet
the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.

To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power
source should meet applicable performance requirements for a limited power source.