IBM SG24-4817-00 User Manual

Page 216

Advertising
background image

This soft copy for use by IBM employees only.

dynamicRouting-LanEmulationServer (3)

}

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

This variable controls the configuration of the
functions in the control point.
This attribute cannot be set in the 8285, when read,
on a 8285 functionsConfiguration is always equal to
dynamicRouting-LanEmulationServer.
When this attribute is set, the configuration of
the functions is saved in the non volatile memory
and the atm subsystem is automatically reset.
When dynamicRouting-noLanEmulationServer is set
the dynamic routing function is active. The selection
of the routes when a connection is established
will be automatic through the SSI ports.
The LAN emulation servers cannot be started if
functionsConfiguration is equal to
dynamicRouting-noLanEmulationServer.
When staticRouting-LanEmulationServer is set, no automatic
route selection accross the SSI ports will be performed
by the atm-subsystem.
The routing will be performed only through the
defined static routes.
The ports cannot be set with the atm access equal to SSI.
All the ports previously configured as SSI ports are
changed to UNI, when the atm-subsystem is restarts after
the change of functionsConfiguration into
staticRouting-LanEmulationServer.
dynamicRouting-LanEmulationServer cannot be set on an
8260.

::= { base 8 }

-- Traps Control

traps OBJECT IDENTIFIER ::= { node 2 }

hello OBJECT-TYPE

SYNTAX INTEGER {

enabled (1),
disabled (2)

}

ACCESS read-write
STATUS mandatory
DESCRIPTION

When disabled, the hello trap is neither sent.
When enabled, the hello trap can be sent by the agent when the
appropriate trap condition is detected.

::= { traps 1 }

-- Physical Description

physical OBJECT IDENTIFIER ::= { node 3 }

-- Switch Control

switchTable

OBJECT-TYPE

200

ATM Workgroup Solutions: Implementing the 8285 ATM Switch

Advertising