DESCRIPTION

Error conditions A to M, as defined in the Q.2110
Specification.
This is the number of received unsolicited or
or inappropriate PDUs.

::= { atmSaalStatsEntry 4 }

atmSaalUnsuccessPdus OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

Error condition O as defined in the Q.2110
Specification.
This is the number of failing retries.

::= { atmSaalStatsEntry 5 }

atmSaalFailedEstablishment OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

Error condition P as defined in the Q.2110
Specification.
This is the number of failing polls.

::= { atmSaalStatsEntry 6 }

atmSaalSequenceGap OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The number of times sequence gaps were
detected by the peer entity.

::= { atmSaalStatsEntry 7 }

atmSaalGapNumbers OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The number of times frames were
re-transmitted due to sequence gaps
detected by the peer entity.

::= { atmSaalStatsEntry 8 }

atmSaalOtherListErrors OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

Error conditions Q to V as defined in the
Q.2110 Specification.

::= { atmSaalStatsEntry 9 }

atmSaalLackOfCredit OBJECT-TYPE

SYNTAX

Counter

ACCESS

read-only

STATUS

mandatory

244