IBM SG24-4817-00 User Manual

Page 289

Advertising
background image

This soft copy for use by IBM employees only.

The subslot number where this Module is located.

It is associated with a slot number. Motherboards are
always located in subslot one, (e.g. <slot>.1). However,
daughter cards can reside on any subslot within the range
(2 ... 8), (e.g. <slot>.<2 .. 8>).

::= { ocInvModEntry 2 }

ocInvModModel OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION

This Module model number.

If the instance value is unknown, Hub will be returned.

::= { ocInvModEntry 3 }

ocInvModSerialNo OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION

This Module serial number.

If the instance value is unknown, N/A will be returned.

::= { ocInvModEntry 4 }

ocInvModHWVer OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION

The revision number of the hardware on this module.

If the instance value is unknown, N/A will be returned.

::= { ocInvModEntry 5 }

ocInvModSWVer OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION

The revision number of the software on this module.

If the instance value is unknown, N/A will be returned.

::= { ocInvModEntry 6 }

ocInvModSWBootVer OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION

The revision number of the boot software on this module.

If the instance value is unknown, N/A will be returned.

::= { ocInvModEntry 7 }

ocInvModMfr OBJECT-TYPE

SYNTAX DisplayString (SIZE(1..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION

The company name that manufactured this module.

If the instance value is unknown, N/A will be returned.

Appendix E.

IBM ATM Campus Switch Private MIBs

273