IPSO DR50 User Manual

Page 14

Advertising
background image

Page 14

Gas Piping Installation

1 . The installation must conform with local codes, or in

the absence of local codes with the National Fuel
Gas Code as, ANSI Z223.1 or the CAN/CGA-
B149, Installation Codes.

2 . Check identification nameplate for type of gas for

dryer.

3. Check the altitude of dryer.

4 . Check with utilities company for proper gas

pressure and gas supply line.

5 . Natural gas only—check the gas pressure inlet

supply to dryer, 11” water column (27.4 mbar)
maximum. Manifold pressure—3.5” water column
(8.8 mbar) pressure .

6 . L.P. gas only—manifold pressure—13” water

column (32.4 mbar) maximum.

CAUTION: Low gas pressure and intermittent
gas will cause gas ignition problems and
inadequate drying of laundry.

GAS PIPING
INSTALLATION

Advertising