The size of the gas service pipe is dependant upon many
variables, such as tees, lengths, etc. Specific pipe size
should be obtained from the gas supplier. Refer to the “Gas
Pipe Size” chart in this manual for general gas pipe size
information.

CAUTION: Gas loop piping must be installed as
illustrated to maintain equal gas pressure for all
dryers connected to a single gas service

Other gas-using appliances should be connected
upstream from the loop.

WARNING:
LIQUIFIED PETROLEUM GASES ONLY !

A gas pressure regulator for liquified petroleum gases is
not furnished on the gas heated clothes dryers. This
regulator is normally furnished by the installer. In
accordance with American Gas Association (AGA)
standards, a gas pressure regulator, when installed
indoors, must be equipped with a vent limiter or a vent
line must be installed from the gas pressure regulator vent
to the outdoors.

Gas Service Installation Instructions

GAS SERVICE
INSTALLATION
INSTRUCTIONS

GAS PRESSURE
REGULATOR FOR
LIQUIFIED
PETROLEUM GASES