26

Digital UNIX

Drivers for the ITI-5232E are on the Digital UNIX distribution kit beginning with
Version 4.0D. Digital UNIX will identify the ITI-5232E as four 21140 based Ethernet
controllers.

Once the hardware is installed in your system, boot the system using genvmunix, in the
following manner:

>>>boot –file genvmunix

This will cause Digital UNIX to scan all hardware devices in the system, and identify the
ITI-5232E . Four 21140 based Ethernet adapters will be identified.

Create a new kernel with support for the four Ethernet ports, identified in genvmunix by
using the doconfig command.

# doconfig

When doconfig completes backup your existing kernel as follows:

# cp /vmunix /vmunix.sav

Then copy the new kernel created by doconfig, to /vmunix, and shutdown and reboot with
your new kernel.

If you are unfamiliar with doconfig, refer to your Digital UNIX documentation for
additional information.

Note: Digital UNIX relies on the settings for media type and speed set by the SRM console.
See Appendix A for more information.