Placing tool in service, Lubrication, Specifications – Ingersoll-Rand 231 User Manual
Page 3
3
PLACING TOOL IN SERVICE
LUBRICATION
Ingersoll--Rand No. 50
Ingersoll--Rand No. 100
Always use of an air line lubricator. We recommend the
following Filter--Lubricator--Regulator Unit:
For International-- No. C28--C4--FKG0
For USA -- No. C28--04--FKG0--28
After each forty--eight hours of operation, or as
experience indicates, inject about 4 cc of the
recommended grease into the Grease Fitting (3).
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
FILTER
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD905--1)
SPECIFICATIONS
Model
Type of
Handle
Drive
Impacts
per min.
Recommended
Torque Range
H
Sound Level
dB (A)
♦Vibrations
Level
in.
ft--lbs (Nm)
Pressure
• Power
m/s
2
231
pistol
1/2” sq.
1,200
25--300
(34--407)
102.0
115.0
5.2
231--2
pistol
1/2” sq. with
extended
anvil
1,200
25--300
(34--407)
102.0
115.0
4.2
H
Tested in accordance with ANSI S5.1--1971 at free speed
♦ Tested to ISO8662--1 loaded with frictionbrake to 9 RPM
•
ISO3744
TPD1884
231
3 Letter
Date Code
location
A __ __