7 +5vdc/+3.3vdc power sequencing, 8 voltage hold-up time – Intel ATX 0.9 User Manual

Page 15

Advertising
background image

Intel ATX Power Supply Design Guide

Version 0.9

Page

15

3.3.7 +5VDC/+3.3VDC Power Sequencing

The +5VDC output level must be equal to or greater than the +3.3VDC output at all times
during power-up and normal operation. The time between the +5VDC output reaching its
minimum in-regulation level and +3.3VDC reaching its minimum in-regulation level must
be less than or equal to 20 ms.

3.3.8 Voltage Hold-up Time

The power supply shall maintain output regulation per Section 3.2.1 despite a loss of input
power at the low-end nominal range (Low = 115 VAC, 57 Hz or 230 VAC, 47 Hz) at
maximum continuous output load as applicable for a minimum of 17 ms.