4 timing / housekeeping control, 1 pwr_ok, 4 timing / housekeeping / control – Intel ATX 0.9 User Manual

Page 16: And t, Are defined in table 9

Advertising
background image

Intel ATX Power Supply Design Guide
Version 0.9

Page 16

3.4 Timing / Housekeeping / Control

PS_ON#

+5VDC/+3.3VDC O/P

PWR_OK

PWR_OK Sense Level = 95% of nominal

Off

On

95%

10%

~

~

~

T2

T3

T5

T4

Figure 1: Power Supply Timing

Notes:

T

2

is defined in Section 3.4.5.

T

3

, T

4

, and T

5

are defined in Table 9.

3.4.1 PWR_OK

PWR_OK is a “power good” signal. It should be asserted high by the power supply to
indicate that the +5VDC and +3.3VDC outputs are above the undervoltage thresholds listed
in Section 3.2.1 and that sufficient mains energy is stored by the converter to guarantee
continuous power operation within specification for at least the duration specified in
Section 3.3.8. Conversely, PWR_OK should be deasserted to a low state when either the
+5VDC or the +3.3VDC output voltages falls below the undervoltage threshold, or when
mains power has been removed for a time sufficiently long such that power supply
operation cannot be guaranteed beyond the hold-up time. The electrical and timing
characteristics of the PWR_OK signal are given in Table 9 and in Figure 1.

Table 9: PWR_OK Signal Characteristics

Signal Type

+5 V TTL compatible

Logic level low

< 0.4 V while sinking 4 mA

Logic level high

Between 2.4 VDC and 5 VDC output while sourcing 200 µA

High state output impedance

1K

from output to common

PWR_OK delay

100 ms < T

3

< 500 ms

PWR_OK rise time

T

5

10 ms

Power down warning

T

4

> 1 ms

Advertising