Industrial Redundant Ring Switch

– RS Series User Manual

TDRS4050601

k

lmask [mask value]

Description

This command enables you to configure relay output activation status when there is

link loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0

corresponds to port 1, etc. (Please refer to Appendix G, Table

– 1.) If the mask bit of

that port(s) is specified by being set up as 1, when there is a link loss occurring on

that port(s), relay output will be activated. The mask value is in hexadecimal format
that represents the 8 bits corresponding binary numbers, it can be either in the form

of i

nitiating “0X” plus a suffix of the hexadecimal number or eliminating “0X”; simply

the hexadecimal number itself. If a mask value is not specified, the

“lmask”

command will display previous assigned mask value.

To assign a mask value for activating relay output when there is link loss occurring
on the port(s), please refer to Appendix G, Table

– 2.

Parameters

Parameter

Description

mask value

Provides the mask value that you want to specify to
configure status of relay when link loss occurs

Example:

cmask [mask value]

Description

This command enables you to configure relay output activation status when there is

communication loss occurring on port(s). The ports are corresponding to the 8 mask
bits, bit 0 corresponds to port 1, etc. (Please refer to Appendix G, Table

– 3.) If the

mask bit of that port(s) is specified by being set up as 1, when there is a

communication loss occurring on that port(s), relay output will be activated. The

mask value is in hexadecimal format that represents the 8 bits corresponding binary

numbers, it can be either in the form of i

nitiating “0X” plus a suffix of the hexadecimal

number or eliminating

“0X”; simply the hexadecimal number itself. If a mask value is

not specified, the

“cmask” command will display previous assigned mask value.

To assign a mask value for activating relay output when there is communication loss

occurring on the port(s), please refer to Appendix G, Table

– 4.