Table

– 10 Corresponding bits and system status (for svalue)

bit Corresponding to:

Condition Description

0

Power 1

a

If there is a power fail
occurring on Power 1, bit 0
will be set as 1.

1

Power 2

b

If there is a power fail
occurring on Power 2, bit 1
will be set as 1.

2

Master Ring Switch
indicator

c

If his Switch is the master
Ring Switch(the Master
LED indicator will be

“on”)

bit 2 will be set as 1.

3

Relay output status d

If the relay output is
activated, bit 3 will be set
as 1.

Table

– 11 Displayed hexadecimal number and current system status conditions

Returned
svalue in
hexadecimal
format

Corresponding 8 bits
binary numbers

Showing current
system status
condition(s):

0

00000000

a

1

00000001

b

2

00000010

c

3

00000011

a or b

4

00000100

c

5

00000101

a or c

6

00000110

b or c

7

00000111

a or b or c

8

00001000

d

9

00001001

a or d

0A

00001010

b or d

0B

00001011

a or b or d

0C

00001100

c or d

0D

00001101

a or c or d

0E

00001110

b or c or d

0F

00001111

a or b or c or d

Table

– 12 Corresponding bits and jumpers

Bit 3

Bit 2

Bit 1

Bit 0

Jumper 3

Jumper 4

Jumper 5

Jumper 6

1

on

1

on

1

on

1

on

0

off

0

off

0

off

0

off