ICP DAS USA TDRS4050601 User Manual

Page 60

Advertising
background image

Industrial Redundant Ring Switch

– RS Series User Manual

TDRS4050601

y

1 or 4 or 5 or 7 or 8

11011001

0Xd9 or d9

2 or 4 or 5 or 7 or 8

11011010

0Xda or da

1 or 2 or 4 or 5 or 7 or 8

11011011

0Xdb or db

3 or 4 or 5 or 7 or 8

11011100

0Xdc or dc

1 or 3 or 4 or 5 or 7 or 8

11011101

0Xdd or dd

2 or 3 or 4 or 5 or 7 or 8

11011110

0Xde or de

1 or 2 or 3 or 4 or 5 or 7 or 8

11011111

0Xdf or df

6 or 7 or 8

11100000

0Xe0 or e0

1 or 6 or 7 or 8

11100001

0Xe1 or e1

2 or 6 or 7 or 8

11100010

0Xe2 or e2

1 or 2 or 6 or 7 or 8

11100011

0Xe3 or e3

3 or 6 or 7 or 8

11100100

0Xe4 or e4

1 or 3 or 6 or 7 or 8

11100101

0Xe5 or e5

2 or 3 or 6 or 7 or 8

11100110

0Xe6 or e6

1 or 2 or 3 or 6 or 7 or 8

11100111

0Xe7 or e7

4 or 6 or 7 or 8

11101000

0Xe8 or e8

1 or 4 or 6 or 7 or 8

11101001

0Xe9 or e9

2 or 4 or 6 or 7 or 8

11101010

0Xea or ea

1 or 2 or 4 or 6 or 7 or 8

11101011

0Xeb or eb

3 or 4 or 6 or 7 or 8

11101100

0Xec or ec

1 or 3 or 4 or 6 or 7 or 8

11101101

0Xed or ed

2 or 3 or 4 or 6 or 7 or 8

11101110

0Xee or ee

1 or 2 or 3 or 4 or 6 or 7 or 8

11101111

0Xef or ef

5 or 6 or 7 or 8

11110000

0Xf0 or f0

1 or 5 or 6 or 7 or 8

11110001

0Xf1 or f1

2 or 5 or 6 or 7 or 8

11110010

0Xf2 or f2

1 or 2 or 5 or 6 or 7 or 8

11110011

0Xf3 or f3

3 or 5 or 6 or 7 or 8

11110100

0Xf4 or f4

1 or 3 or 5 or 6 or 7 or 8

11110101

0Xf5 or f5

2 or 3 or 5 or 6 or 7 or 8

11110110

0Xf6 or f6

1 or 2 or 3 or 5 or 6 or 7 or 8

11110111

0Xf7 or f7

4 or 5 or 6 or 7 or 8

11111000

0Xf8 or f8

1 or 4 or 5 or 6 or 7 or 8

11111001

0Xf9 or f9

2 or 4 or 5 or 6 or 7 or 8

11111010

0Xfa or fa

1 or 2 or 4 or 5 or 6 or 7 or 8

11111011

0Xfb or fb

3 or 4 or 5 or 6 or 7 or 8

11111100

0Xfc or fc

1 or 3 or 4 or 5 or 6 or 7 or 8

11111101

0Xfd or fd

2 or 3 or 4 or 5 or 6 or 7 or 8

11111110

0Xfe or fe

1 or 2 or 3 or 4 or 5 or 6 or 7 or 8

11111111

0Xff or ff

Table

–3 Corresponding bits and ports (for cmask command)

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Port 8

Port 7

Port 6

Port 5

Port 4

Port 3

Port 2

Port 1

1

on

1

on

1

on

1

on

1

on

1

on

1

on

1

on

0

off

0

off

0

off

0

off

0

off

0

off

0

off

0

off

Table

– 4 Assign mask value for activating relay output when there is communication loss occurring on

the port(s)

Activate relay output when there
is a communication loss occurring
on port(s):

Corresponding
8 bits binary
numbers

Mask
value

N/A

00000000

0X0 or 0

1

00000001

0X1 or 1

2

00000010

0X2 or 2

1 or 2

00000011

0X3 or 3

Advertising