Ole_link17, Ole_link18, Ole_link10 – ICP DAS USA TDRS4050601 User Manual

Page 56: Appendix g, Tables

Advertising
background image

Industrial Redundant Ring Switch

– RS Series User Manual

TDRS4050601

u

Appendix G

Tables

Table

– 1 Corresponding bits and ports (for lmask command)

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Port 8

Port 7

Port 6

Port 5

Port 4

Port 3

Port 2

Port 1

1

on

1

on

1

on

1

on

1

on

1

on

1

on

1

on

0

off

0

off

0

off

0

off

0

off

0

off

0

off

0

off

Table

– 2 Assign mask value for activating relay output when there is link loss occurring on the port(s)

Activate relay output when there
is a link loss occurring on port(s):

Corresponding
8 bits binary
numbers

Mask
value

N/A

00000000

0X0 or 0

1

00000001

0X1 or 1

2

00000010

0X2 or 2

1 or 2

00000011

0X3 or 3

3

00000100

0X4 or 4

1 or 3

00000101

0X5 or 5

2 or 3

00000110

0X6 or 6

1 or 2 or 3

00000111

0X7 or 7

4

00001000

0X8 or 8

1 or 4

00001001

0X9 or 9

2 or 4

00001010

0Xa or a

1 or 2 or 4

00001011

0Xb or b

3 or 4

00001100

0Xc or c

1 or 3 or 4

00001101

0Xd or d

2 or 3 or 4

00001110

0Xe or e

1 or 2 or 3 or 4

00001111

0Xf or f

5

00010000

0X10 or 10

1 or 5

00010001

0X11 or 11

2 or 5

00010010

0X12 or 12

1 or 2 or 5

00010011

0X13 or 13

3 or 5

00010100

0X14 or 14

1 or 3 or 5

00010101

0X15 or 15

2 or 3 or 5

00010110

0X16 or 16

1 or 2 or 3 or 5

00010111

0X17 or 17

4 or 5

00011000

0X18 or 18

1 or 4 or 5

00011001

0X19 or 19

2 or 4 or 5

00011010

0X1a or 1a

1 or 2 or 4 or 5

00011011

0X1b or 1b

3 or 4 or 5

00011100

0X1c or 1c

1 or 3 or 4 or 5

00011101

0X1d or 1d

2 or 3 or 4 or 5

00011110

0X1e or 1e

1 or 2 or 3 or 4 or 5

00011111

0X1f or 1f

6

00100000

0X20 or 20

1 or 6

00100001

0X21 or 21

2 or 6

00100010

0X22 or 22

1 or 2 or 6

00100011

0X23 or 23

3 or 6

00100100

0X24 or 24

1 or 3 or 6

00100101

0X25 or 25

2 or 3 or 6

00100110

0X26 or 26

1 or 2 or 3

or 6

00100111

0X27 or 27

Advertising