Wiring the ex-2714 system cable – Icom MR-1000TTM User Manual

Page 31

Advertising
background image

27

9

INSTALLATION AND CONNECTIONS

Wiring the EX-2714 system cable

q Loosen the four bolts using a hex head wrench on

the bottom of the scanner unit, and open the unit.

w Loosen the nut on the scanner unit and pass the

system cable through the nut and sealing tube.

e Insert the PA cable (black and white) connector to

the PA unit connector J1. (*1; Be sure to follow the
following diagram carefully)

r Connect the shielding wire to the ground plate with

the screw as shown in the diagram.

t Clamp the system cable with the ferrite bead at-

tached near the sealing connector. Be sure to clamp
it tightly.

• Scanner unit disassembly

y Connect the power cable (black and red) end to the

power unit connector. (*2; Be sure to follow the fol-
lowing diagram carefully).

u Tighten the sealing-nut, then replace the radome

cover over the scanner unit.
DO NOT stretch the system cable too much, other-
wise miss contact of the connector may occur.

i Tighten the four bolts on the bottom of the scanner

unit.
• The four projections around the circumference of

the radome cover show the positions of the bolt
receptacles.

CAUTION:

NEVER cut the supplied system cable.

Ship’s bow direction

Face the Ω mark in the direction
of the ship’s bow.

Stern

System cable

Scanner unit disassembly

• Connect the system cable

Ferrite bead

Shielding
wire

PA cable

Power cable

Round the PA
cable twice.

Sealing tube

Nut

*2; Power
connector

*1; PA cable

MR-1000R2_T2.qxd 04.2.24 10:22 Page 27