33

11

SERVICE MAN MENU

TIMING adjustment

The system cable length affects the sweep timing.
When the cable length adjustment is not correct, a
straight target is shown as a curved echo. Thus, cable
length adjustment is necessary.

q Position your boat near a straight target such as

breakwater, wharf, etc.

w Push [–]/[

] several times to select

1

8

or

1

4

NM

range.

e Push [TX (SAVE)]/[

] to display the target

on the screen.

r Push [MENU]/[

], [Ú] and [

] several times to

display the “SERVICE MAN” menu.

t Push [Ú] until the “TIMING ADJ.” section becomes

highlighted.

y Push [

Ω ≈

] to adjust the echo until it becomes

straight. (see below)

u Push [MENU]/[

] to return to the normal screen.

Proper adjustment

Improper, pulling inward

Improper, pushing outward

HDG adjustment

If the heading marker line differs from the exact bow
direction, correct the heading marker line as follows.
This function may be helpful when the scanner has not
been mounted exactly in the direction of the bow.

q Line up the bow of the boat with an identifiable tar-

get.

w Push [TX (SAVE)]/[

] to display the target

on the screen.

e Push [MENU]/[

], [Ú] and [≈] several times to

display the “SERVICE MAN” menu.

r Push [Ú] until the “HDG ADJ.” section becomes

highlighted.

t Push [Ω ≈] to adjust, until the target matches the

heading marker. (the difference can be read out on
the menu screen)

y Push [MENU]/[

] to return to the normal screen.

1

T.V E C T

0.000N M

NM

C U R S

S O G

H U P

0 0 0 . 0 ˚

R

H D G

IR

ES

SERVICE MAN

SPD ADJ.

0.0

˚

HV

SETUP MEMORY

RANGE

2 4 0 0 0

MONITOR
HEATER

5 7 3 1 . 0 H

TX TIME

3 0 . 0

OUTPUT

ENGLISH

VOLTAGE

MG

3 4 0

7 5

3 . 0

0 . 5 5

TIMING ADJ.

1/8

3/4

2

6

16

36

1/4

1

3

8

24

1/2

1.5

4

32

HDG ADJ.

1

T.V E C T

0.000N M

NM

C U R S

S O G

H U P

0 0 0 . 0 ˚

R

H D G

IR

ES

SERVICE MAN

SPD ADJ.

10.0

˚

HV

SETUP MEMORY

RANGE

2 4 0 0 0

MONITOR
HEATER

5 7 3 1 . 0 H

TX TIME

3 0 . 0

OUTPUT

ENGLISH

VOLTAGE

MG

3 4 0

7 5

3 . 0

0 . 5 5

TIMING ADJ.

1/8

3/4

2

6

16

36

1/4

1

3

8

24

1/2

1.5

4

32

HDG ADJ.

48

12

48

12

Push [Ω ≈]

Angle of difference

MR-1000R2_T2.qxd 04.2.24 10:22 Page 33