Cornelius 700 - Series User Manual

Page 19

Advertising
background image

Continuous Flow Icemaker Service Manual

© 2004-2005, IMI Cornelius Inc.

- 15 -

Publication Number: 630460174SER

M

OTOR

C

HECK

The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low
readings must be used. The start relay cover must be removed.

If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test,
replace gearmotor.

S

TART

R

ELAY

1.

Check between “2” and “4” on relay (with relay unplugged). If there is continuity replace the relay, as

the relay contacts should be open.

2.

Check between “3” and “4” on relay, if no continuity replace the relay.

FIGURE 14. GEARMOTOR ASSEMBLY

T

O

R

EPLACE

G

EARMOTOR

A

SSEMBLY

1.

Disconnect the icemaker from the electrical power source.

2.

Disconnect the transmission cable from the electrical box.

3.

Remove the 4 hex head bolts securing the evaporator to the top of the transmission.

4.

Remove the 4 bolt’s holding the transmission and bracket to frame base, while supporting the

weight of the evaporator. Remove the transmission from the unit.

5.

When replacing the transmission, it may be necessary to rotate the auger back and forth to align

the motor shaft and auger.

FIGURE 15. AUGER AND EXTRUDING HEAD REMOVAL

AUGER NUT

BEARING NYLON

GROOVE

EXTRUDING

HEAD

BEARING DELRIN

ANTI–ROTATION

RIB – 3 PLACES

AUGER

“D” DRIVE

Advertising