500 a – Cornelius 700 - Series User Manual

Page 20

Advertising
background image

Continuous Flow Icemaker Service Manual

Publication Number: 630460174SER

- 16 -

© 2004-2005, IMI Cornelius Inc.

I

NSTALLATION

AND

S

HAFT

S

EAL

R

EPLACEMENT

500

A

UGER

AND

E

XTRUDING

H

EAD

R

EMOVAL

1.

Disconnect unit from power supply.

2.

Remove storage container cover and put aside.

3.

Turn off water supply to icemaker.

4.

After ice has melted from head take hold of the auger nut and lift straight up to disengage from

icemaker.

5.

When replacing the auger assembly, make certain that both the auger engages the output shaft

drive and the extruding head ribs engage the evaporator tube.

1.

Place shaft seal locator seat over gear

motor output shaft, embossed side down,
and push down until shaft seal seat rests
flush on top of gear motor.

2.

Place rubber coated ceramic seal

(important: ceramic face up) over output
shaft and push down until seal rests on top
of the shaft seal seat. (Lubricate rubber on
ceramic seal with rubber lubricant.)

3.

Place shaft seal with carbon face down

(spring up) over output shaft and push
(gently) downward until seal rests on
ceramic face of the output shaft seal.

4.

Place flat washer over output shaft and let

rest on the output shaft seal. Push down
on the washer compressing the spring on
the output shaft seal. While holding the
seals (down) in place slide the E–ring into
the groove on the output shaft.

FIGURE 16. SHAFT SEAL 500

E–RING

WASHER, PLAIN FLAT

SHAFT SEAL

LOCATOR SEAL

GEARMOTOR