TROUBLESHOOTING CHART - ICEMAKER NOT OPERATING

NO POWER

Check electrical wiring in con
trol box for loose connec

tions.
Check for failed service

switch or relay.
Check power to machine.

ICEMAKER RUNS BUT
DOES NOT MAKE ICE

Condenser fan running

but compressor not running

Check line voltage.

Check compressor winding
& components.

LOW WATER SAFETY

SWITCH OPEN

Remote condenser
not running.

Evaporator water tube

may have an air bubble.
Clear air bubble from

tube.

Check power

to condenser.

Check electrical

wiring in control box
for loose connections.

High pressure

switch open or
cycling on and off.

Check that water is turned on.

Check for restriction in water line.
Check incoming water pressure

(minimum 10 lbs.).
Check water safety switch.

ICEMAKER OPERATING BUT
SOFT ICE

Check bin switch

Clean all related

drain lines.

Refer to guide

to Good Ice in
service manual.

GEARMOTOR OVERLOAD

TRIPPED

Check water level control
and evaporator water tube

for lime build up restriction.

CAUTION

Clear ice from
evaporator and

auger before re
setting over
load.

CLEAN
see

instructions.

Reset
overload.

Icemaker runs

Reset but
motor does

not run.

Will not
reset.

Overload

hot try
again.

Will not

reset
replace

overload

Check

gearmotor
circuit.

Short run trips

again in 2 min
utes. Check gear

motor circuit.

IMPORTANT

Icemaker runs when reset
but problem has not been

found.
Continue checking for
overload as follows to

guard against future
problems

Low suction pressure

(20 lbs. or below).

TXV bulb

lost charge.

Replace valve
evacuate and

recharge.

High suction pressure

(30 lbs. or above).

Suction line

not
insulated.

Bulb

uninsulated.

Clean and

insulate.

TXV not

operating
properly.

Bulb

loose.

Clean

and
tighten.

Head

Pressure
high.

Valve

stuck
open.

Replace

valve.

Condenser

dirty or
restricted.

Condenser

fan not
running.

Too much

refrigerant in
system.

Non-condensible

in system.

Discharge

king valve
partially

closed.

Open

valve

Evacuate and

recharge system.
Clean condenser.

Check electrical circuit

to fan motor.
Check fan motor.

Low pressure switch open

or cycling on and off.

Low on
refrigerant.

Plugged
liquid line

dryer.

Restricted
liquid line.

Plugged or

faulty TXV.

Icemaker

froze up.

Check if

auger is
turning.

Replace

valve.
Evacuate

and
recharge
system.

Check for

kinks or
damage to

liquid line.

Replace

dryer.
Evacuate

and
recharge
system.

LAC not operating

properly (minimum
discharge pressure

180 lbs.).

Check for

leaks.

Replace LAC valve,

evacuate and
recharge system.

Check drive on
gearmotor.

Check gears in
gearbox.

Check if extruding

head is down in
evaporator tube.

OVERLOAD GUIDE
ELECTRICAL

High or low voltage weak power lines can cause overloads on icemaker restarts
High running current. Check motor circuits and start relay - Auger delay failed.

ICEMAKER
Mechanical parts worn. Scored evaporator or auger. Worn thrust bearing.

Ice maker not turning off. Failed ice level control.
Over compression. Low water inlet temperature. Restriction in water line from

reservoir.
REFRIGERANT
Contaminated charge or bad compressor.

Low charge or gas leak.
Low suction pressure. Improper expansion valve sensing bulb. Location or insulation

and/or defective expansion valve

No

Remote condenser
units only

Remote condenser

units only

No

Yes

Yes

No