Packet operation, D connections for packet, D data socket – Icom I706MKTMG User Manual

Page 40

Advertising
background image

37

4

RECEIVE AND TRANSMIT

Packet operation

D Connections for packet

Rear panel

DATA

PTT

PTTP

DATA IN

SQL

RX AUDIO

GND

TX AUDIO

TNC SIDE

TU or TNC

RS-232C

Personal computer

q

w

e

y

t

r

AF OUT

DATA OUT

GND

SQ

q

w

e

y

t

r

PIN #/NAME

DESCRIPTION

q DATA IN

Communication data input.

w GND

Ground for DATA IN, DATA OUT and AF OUT.

e PTTP

Transmits when grounded.

r DATA OUT

Outputs 9600 bps receive data.

t AF OUT

Outputs 1200 bps receive data.

y SQ

Squelch output.

Goes to ground when squelch opens.

Rear panel view

D Adjusting the transmit signal output from the TNC

NOTE: For packet operation the transceiver can

be set to one of two data speeds: 1200 bps or
9600 bps. Data speed is set in initial set mode
(see p. 54 item 29 9600 MODE).

Data speed is set in initial set mode (see p. 53 item
29 9600 MODE).When setting data transmission
speed to 9600 bps, the

DATA

signal coming from the

TNC is applied exclusively to the internal limiter cir-
cuitry to automatically maintain bandwidth.
NEVER apply data levels from the TNC of over 0.6
Vp-p, otherwise the transceiver will not be able to
maintain the band width and may possibly interfere
with other stations.

NOTE: Read the instructions supplied with your

TNC carefully before attempting packet operation
with the IC-706MKIIG.

1. When using a level meter or synchroscope, adjust

the TX audio level (

DATA IN

level) from the TNC as

follows.
0.4 Vp-p (0.2 Vrms): recommended level

0.2 Vp-p–0.5 Vp-p (0.1 Vrms–0.25 Vrms):
acceptable level

2. When not using a measuring device.

Connect the IC-706MKIIG to a TNC.

Enter a test mode (“CAL”, etc.) on the TNC, then
transmit some test data.

When the transceiver fails to transmit test data or
transmits sporadically (TX indicator doesn’t appear
or flashes):

Decrease the TNC output level until the transmit
indicator lights continuously.

When transmission is not successful even though
the TX indictor lights continuously:

Increase the TNC output level.

D Data socket