Mb-72, D installation, D operation – Icom I706MKTMG User Manual

Page 64

Advertising
background image

61

OPTIONAL INSTALLATIONS/SETTINGS

10

UT-106

DSP RECEIVER UNIT

D Installation

Open the transceiver case as shown on p. 59.

Remove the 4-pin connector (P251) from J1413 on
the MAIN unit (top side) and plug it into J1 of the
UT-106 on the PLL unit (bottom side).

Plug the 4-pin connector (P1) from the UT-106 into
J1413 on the MAIN unit.

Plug the supplied ribbon cable into J3 on the UT-
106 and J253 on the PLL unit.

• Be careful of the orientation of the ribbon cable.

Attach the UT-106 to the PLL unit, using the exist-
ing guide for alignment, as illustrated at right.

Reassemble the transceiver.

DOperation

Refer to the instructions supplied with the UT-106 for
operating details.

MB-72

CARRYING HANDLE

The optional MB-72

CARRYING HANDLE

is convenient

when carrying the transceiver for DX’peditions, field
operation, etc.

Remove the 2 screws from the right side of the
transceiver as shown below.

Replace those with 2 supplied screws plus rubber

feet and additionally attach 2 more supplied
screws (including rubber feet) as shown below.

• When replacing the 2 screws at the rear, be sure to

squeeze the top and bottom covers together to ensure
proper alignment.

Attach the MB-72 to the left side of the transceiver
as shown below.

rubber
feet

carrying
handle

J1

P251

MAIN unit

UT-106

unit position

PLL unit

Remove the J1431 connector
from the PLL unit and replace
with the UT-106 connector

Be careful of the orientation
when connecting the
ribbon cable.

P1

J1431

P253

P1

J3

J1