21. Using more than one Fireface


OS X supports the usage of more than one audio device within an audio software. This is done
via the Core Audio function Aggregate Devices, which combines several devices into one.

The current driver supports up to three Fireface 400 or 800. All units have to be in sync, i.e.
have to receive valid sync information (either via word clock or by using AutoSync and feeding
synchronized signals).

• If one of the Firefaces is set to clock mode Master, all others have to be set to clock mode

Slave, and have to be synced from the master, for example by feeding word clock. The
clock modes of all units have to be set up correctly in the Fireface Settings dialog.

• If all units are fed with a synchronous clock, i.e. all units show Sync in their Settings dialog,

all channels can be used at once.


When using more than one Fireface 400/800 the FireWire bus might get overloaded. To prevent
this connect all units to different busses.

Note: TotalMix is part of the hardware of each Fireface. Up to three mixers are available, but
these are separated and can't interchange data. Therefore a global mixer for all units is not
possible.

22. DIGICheck Mac


The DIGICheck software is a unique utility developed for testing, measuring and analysing digi-
tal audio streams. Although this Windows software is fairly self-explanatory, it still includes a
comprehensive online help. DIGICheck 0.65 operates in parallel to any software, showing all
input data. The following is a short summary of the currently available functions:

Level Meter. High precision 24-bit resolution, 2/10/28 channels. Application examples: Peak

level measurement, RMS level measurement, over-detection, phase correlation measure-
ment, dynamic range and signal-to-noise ratios, RMS to peak difference (loudness), long
term peak measurement, input check. Oversampling mode for levels higher than 0 dBFS.
Supports visualization according to the K-System.

Hardware Level Meter for Input, Playback and Output. Reference Level Meter freely con-

figurable, causing near zero CPU load, because calculated from the Fireface hardware.

Spectral Analyser. World wide unique 10-, 20- or 30-band display in analog bandpass filter

technology. 192 kHz-capable!

Vector Audio Scope. World wide unique Goniometer showing the typical afterglow of a

oscilloscope-tube. Includes Correlation meter and level meter.

Totalyser. Spectral Analyser, Level Meter and Vector Audio Scope in a single window.
Surround Audio Scope. Professional Surround Level Meter with extended correlation

analysis, ITU weighting and ITU summing meter.

ITU1770/EBU R128 Meter. For standardized loudness measurements.
Bit Statistics & Noise. Shows the true resolution of audio signals as well as errors and DC

offset. Includes Signal to Noise measurement in dB and dBA, plus DC measurement.

Completely multi-client. Open as many measurement windows as you like, on any chan-

nels and inputs or outputs!


To install DIGICheck, go to the \DIGICheck directory on the RME Driver CD and run setup.exe.
Follow the instructions prompted on the screen.

DIGICheck is constantly updated. The latest version is always available on our website
www.rme-audio.com, section Downloads / DIGICheck.