IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com



5.0 SAFETY

Condensate disposal

Condensate cannot be discharged into fresh/surface
water drains. In some regions compressor condensate
containing ULTRA COOLANT can be fed directly into a
drainage system that has downstream sewage treatment.

As waste water regulations vary by country and region it
is the responsibility of the user to establish the limitations
and regulations in their particular area. Ingersoll Rand
and its associated distributors are happy to advise and
assist in these matters.

Coolant disposal

Steps to be taken in the case of spillage: Soak up with a
suitable absorbent material, then sweep into a plastic bag
for disposal.

Burn in an approved incinerator, or according to local area
or country regulations.

For further information, consult ULTRA COOLANT Material
Data Sheets ACGP 011/96 or APDD 236. FOOD GRADE
COOLANT Material Data Sheets IRACA145 or APDD190.

WARNING

This compressor contains a variable frequency drive. When it is switched off and the motor is stopped, the

internal capacitors store a potentially lethal high voltage. DO NOT REMOVE THE DRIVE COVER or attempt any

work on the drive unless trained. There are no user serviceable items behind the cover.

WARNING

There is a high discharge air temperature shutdown function built into each compressor. lt is factory preset

at 109 °C (228° F).This function should be checked at regular intervals for proper operation, once a month is

recommended. Refer to maintenance section.
Failure to adhere to these recommendations can result in mechanical failure, property damage and serious

injury or death.

All air and water inlet, and air and water discharge pipework to and from the inlet and discharge port

connections must take into account vibration, pulsations, temperature, maximum pressure applied,

corrosion and chemical resistance. In addition, it should be noted that lubricated compressors will

discharge some oil into the air stream; therefore, compatibility between discharge piping, system

accessories and software must be assured.
For the foregoing reasons, the use of plastic piping and rubber hose as discharge piping is not

recommended. In addition, flexible joints and/or flex lines can only be considered for such purposes if

their specifications fit the operating parameters of the system.
It is the responsibility of the installer and owner to provide the appropriate service pipework to and from

the machine.

WARNING

“Ingersoll Rand air compressors are not designed, intended, or approved for breathing air applications.

Ingersoll Rand does not approve specialized equipment for breathing air application and assumes no

responsibility or liability for compressors used for breathing air services.”

WARNING

No portable communication devices emitting more than 7.5 volts per metre in the frequency range from 250

MHz to 280 MHz should be operated within 5m (16.5ft) of the unit.

WARNING

The motor rotor contains a powerful magnetic field. This field can effect the operation of digital devices such

as watches, mobile phones etc. Assembly or handling of the rotor should not be attempted by personnel with

cardiac pacemakers, defibrillators or other implanted electronic medical device.

WARNING

The specification of this machine is such that the machine is not suitable for use in flammable gas risk areas.

If such an application is required then all local regulations, codes of practice and site rules must be observed.

To ensure that the machine can operate in a safe and reliable manner, additional equipment such as gas

detection and intake (shut−off) valves may be required, dependant on local regulations or the degree of risk

involved.

WARNING

The compressor can operate in a pressurized shutdown mode. If the compressor stops automatically, the

airend, separator tank and oil system can contain high pressure air. This can be relieved by pressing the

emergency stop button and can be verified by unscrewing the coolant fill plug which has a vent hole through

which any residual pressure will be vented. Downstream of the separator tank may still contain system

pressure which must also be vented