10.0 MAINTENANCE

Note:

On some sea watercooled models the oil cooler and aftercooler are fitted with sacrificial zinc anodes (pencils) that are
located in the end bonnets of the coolers. These sacrificial zinc anodes should be checked after the first 50 hours of
operation to determine if corrosive conditions exist. If satisfactory this interval may be extended to 500 hours.

NOTE:

If sacrificial zinc anode is 50% corroded it should be replaced.

Coastal/harbor waters can contain corrosive chemicals from pollution and may reduce anode/cooler life.

Effects of corrosion or erosion are specifically excluded from warranty considerations.

1.

2.

3.

10.3 MAINTENANCE PROCEDURES

CAUTION

Before beginning any work on the compressor, read and understand the safety instructions earlier on in this

manual. Open, lock and tag the main electrical disconnect and close the isolation valve on the compressor

discharge. Do not under any circumstances open any drain valve or remove components from the compres-

sor until this has been carried out. Ensure that all pressure has been vented from the compressor. Verify this

by slowly unscrewing the coolant fill cap one turn. Unscrewing the fill cap opens a vent hole, drilled in the

cap, allowing pressure to release to atmosphere. Do not remove the fill cap until all pressure has vented from

the unit. Note that pipework downstream of the separator tank may still contain pressure that must also be

vented to atmosphere before beginning any work.

CAUTION

When using any form of liquid for cleaning, ensure that all electrical components are protected or
covered to prevent ingress of liquid.

WARNING

This compressor contains a variable frequency drive. When it is switched off and the motor is stopped, the

internal capacitors store a potentially lethal high voltage. DO NOT REMOVE THE DRIVE COVER or attempt any

work on the drive unless trained. There are no user serviceable items behind the cover.

DANGER

This compressor contains a variable frequency drive. When it is switched off and the motor is stopped, the

internal capacitors store a potentially lethal high voltage electric charge which gradually falls to zero over

time. After switching off the machine at its local isolator WAIT AT LEAST 15 MINUTES for the capacitors to fully

discharge before opening the power drive module doors.

WARNING

The compressor can operate in a pressurised shutdown mode. If the compressor stops automatically, the

airend, separator tank and oil system can contain high pressure air. This can be relieved by pressing the

emergency stop button and can be verified by unscrewing the coolant fill plug which has a vent hole through

which any residual pressure will be vented. Downstream of the separator tank may still contain system pres-

sure which must also be vented.

WARNING

Use suitable equipment for lifting heavy items and ensure loose components are adequately supported to

eliminate risk of dropping.

WARNING

The motor rotor contains a powerful magnetic field. This field can effect the operation of digital devices such

as watches, mobile phones etc. Assembly or handling of the rotor should not be attempted by personnel with

cardiac pacemakers, defibrillators or other implanted electronic medical device.

Advertising