9.0 OPERATING INSTRUCTIONS

9.7 OPTIONS

Options are turned on or off and their associated values are set
using the OPTION screen shown opposite.

Some options are purchased, they require additional machine
hardware and must first be enabled by service personnel. The name
and value of each of the following options can be seen by moving
the list up and down using the arrow buttons

An Option item’s value can be changed the same way that
OPERATOR SETPOINTS values are changed.

100

PSI

READY TO START

−OPTIONS−

REMOTE START/STOP ON

REMOTE START/STOP ON

STATUS

MAIN MENU

SELECT

OPTIONS Items

SELECTION

MIN.

MAX.

Step

Unit

Installed

Option

Required

Remote Pressure Sensor

ON/OFF

No

Sequencer

ON/OFF

No

Remote Start/Stop

ON/OFF

Yes

Power Out Restart

ON/OFF

Yes

Power Out Restart Time

10

600

1

SEC

Yes

Scheduled Start Day

day

day

1

day

Yes

Scheduled Start

00:00

23:59

1

time

Yes

Scheduled Stop Day

day

day

1

day

Yes

Scheduled Stop

00:00

23:59

1

time

Yes

Modbus Protocol

ON/OFF/ICU

No

Modbus Address

1

247

1

No

Remote pressure sensor

If this setting is set to ON, the compressor will use a remote
mounted pressure sensor for controlling system pressure by
comparing it to the Target Pressure setting and the Auto Stop
Pressure setting. The pressure measured by this sensor is shown in
the CURRENT STATUS display as the Remote Pressure reading. The
local sensor at the package discharge is still used for Immediate
Stop, for certain Alarm conditions and for display on the left side of
the screen.

Sequencer

If this setting is set to ON, the compressor will be able to start and
stop by commands from a host device. When the Intellisys receives
a load command from the host device, the compressor will start.
When the Intellisys receives an unload command the compressor
will respond as though executing an immediate stop.

Remote start/stop

If the remote start/stop option is installed and this setting is set
to ON, the compressor can be started and stopped from a remote
device.

Power out restart

If this setting is set to ON, the compressor will automatically restart
when power is returned to the compressor if it was operating when
power was removed.

Note:
A kit including instruction manual is required to install this option.

Power out restart time

If the power out restart setting is set to ON, this is the number of
seconds from the time power is restored until the compressor starts.
The power out restart horn will sound during this time.

Scheduled start day

This option is the selection for the day that a scheduled start will
take place. The selections are Sunday, Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday, Daily (Su- Sa), Weekdays (M - F), or
Weekends. This option setpoint will work with the scheduled start
setpoint.