ADVANCED FEATURES

USING DIAGNOSTIC

If you are using multiple transducers, switch between transducers to
confirm the connections for each.

Boat Speed/Water Temperature Connection. Other connections tested
include the boat speed and surface water temperature sensors. These
accessory sensors can be purchased independently or together as a single
sensor (see the Humminbird Accessories catalog). If the sensors are
connected and working properly, a “connected” message appears.

The speed input feature only works when the boat is in motion as the
paddle wheel on the speed sensor must rotate to be detected.

Voltage Input. Another connection tested is the voltage input, and is
especially helpful in diagnosing input voltage problems. The current input
voltage is displayed. If voltage fluctuations or power supply in excess of 20
VDC or less than 10 VDC is suspected, use the diagnostic screen to confirm
input voltage. Often, small outboard motors do not effectively regulate
voltage when operated at high engine speeds.

Use Diagnostic while running the boat at high speeds to show the voltage
gain. Also, if you are using the 450TX in a portable configuration or from
the trolling motor battery, Diagnostic can be used to evaluate the health of
the battery by showing the current voltage.

Total Time. The total time category indicates the total time the unit has
been in use since shipped from the factory. It is normal for some hours to
appear in the total time when the unit is new due to factory testing. While

Upper Range Limit

Amplitude Readout

Sonar Return

Lower Range Limit

Depth

27