Chapter 7. Symptom-to-FRU index

95

SCSI error codes

Temperature error messages

01298101

(Bad update data for

processor 1)

1.

Ensure all processors are the same stepping level and cache size.

2.

Processor 1

01298102

(Bad update data for

processor 2)

1.

Ensure all processors are the same stepping level and cache size.

2.

Processor 2

I9990301

(Fixed boot sector error)

1.

Hard Disk Drive

2.

Cable

3.

SCSI Backplane

4.

System Board

I9990305

(Fixed boot sector error,

no operating system installed)

1.

Install operating system to hard disk drive.

I9990650

(AC power has been

restored)

1.

Check power cable

2.

Check for interruption of power supply

3.

Power Cable

Error Code

FRU/Action

All SCSI Errors

One or more of

the following might be causing the problem:

A failing SCSI device (adapter, drive,
controller)

An improper SCSI configuration or SCSI
termination jumper setting

Duplicate SCSI IDs in the same SCSI
chain

A missing or improperly installed SCSI
terminator

A defective SCSI terminator

An improperly installed cable

A defective cable

1.

External SCSI devices must be powered-on before you power-on
the server.

2.

The cables for all external SCSI devices are connected correctly.

3.

If you have attached an external SCSI device to the server, make
sure the external SCSI termination is set to automatic.

4.

The last device in each SCSI chain is terminated correctly.

5.

The SCSI devices are configured correctly.

Message

Action

DASD Over recommended Temperature
(sensor X)

(level-warning; DASD

bay "X" had over temperature condition)

1.

Ensure system is being properly cooled

; see “Temperature

checkout” on page 26.

DASD under recommended temperature
(sensor X)

(level-warning; direct access

storage device bay "X" had under
temperature condition)

1.

Ambient temperature must be within normal operating
specifications

; see “Features and specifications” on page 4.

Error Code/Symptom