Table 1. Features and Specifications.

Microprocessor:

Intel

®

Pentium

®

III

microprocessor with MMX™
technology and SIMD
extensions

256 KB Level-2 cache

Supports up to two
microprocessors

Memory:

Standard: 256 MB

Maximum: 4 GB

Type: 133 MHz, ECC, SDRAM,
Registered DIMMs

Slots: 4 dual inline

Drives standard:

Diskette: 1.44 MB

CD-ROM: 24X IDE

Expansion bays:

Two 3.5-inch slim high bays for
LVD SCSI hard disk drives

PCI expansion slots:

Two 33 MHz/64-bit

Power supply:

One 200 watt (115-230 Vac)

Video:

S3 Savage4 PRO
Graphics/Video Accelerator
(integrated on system board)

Compatible with SVGA

8 MB SDRAM video memory

Size

Height 43.69 mm (1.72")

Depth: 653.29 mm (25.72")

Width: 439.93 mm (17.32")

Weight: approximately 12.7 kg
(28lb) when fully configured

Integrated functions:

Advanced System Management
processor

One Ultra160 SCSI controller

Two 10BASE-T/100BASE-TX
Intel Ethernet controllers

Two Universal Serial Bus (USB)
ports

Two RS-485 Advanced System
Management processor ports
(one In, one Out)

One serial port

Two Cable Chaining Technology
ports (IN, OUT)

Acoustical noise emissions:

Sound power, idling: 6.1 bel
maximum

Sound power, operating: 6.2 bel
maximum

Environment:

Air temperature:

— Server on: 10º to 35º C (50.0º to

95.0º F). Altitude: 0 to 914 m
(2998.7 ft.)

— Server on: 10º to 32º C (50.0º to

89.6º F). Altitude: 914 m
(2998.7 ft.) to 2133 m (6998.0 ft.)

— Server off: 10º to 43º C (50.0º to

109.4º F). Maximum altitude:
2133 m (6998.0 ft.)

Humidity:

— Server on: 8% to 80%

— Server off: 8% to 80%

Heat output:

Approximate heat output in British
Thermal Units (BTU) per hour

Minimum configuration: 273 BTU
(80 watts)

Maximum configuration: 751 BTU
(220 watts)

Electrical input:

Sine-wave input (50-60 Hz)
required

Input voltage low range:

— Minimum: 100 V ac

— Maximum: 127 V ac

Input voltage high range:

— Minimum: 200 V ac

— Maximum: 240 V ac

Input kilovolt-amperes (kVA)
approximately:

— Minimum: 0.08 kVA

— Maximum: 0.22 kVA