Fan error messages, System shutdown, Voltage related system shutdown – IBM xSeries 330 User Manual

Page 104: Fan error messages system shutdown

Advertising
background image

96

Hardware Maintenance Manual: xSeries 330

Fan error messages

System shutdown

Refer to the following tables when experiencing system shutdown related to voltage
or temperature problems.

Voltage related system shutdown

DASD 1 Over Temperature

(level-critical;

sensor for DASD1 reported temperature
over recommended range)

1.

Ensure system is being properly cooled

; see “Temperature

checkout” on page 26.

Power Supply "X" Temperature Fault

(level-critical; power supply "x" had over
temperature condition)

1.

Ensure system is being properly cooled;

see “Temperature

checkout” on page 26.

2.

Replace Power Supply "X"

System board is over recommended
temperature

(level-warning; system board

is over recommended temperature)

1.

Ensure system is being properly cooled

; see “Temperature

checkout” on page 26.

2.

Replace system board

System board is under recommended
temperature

(level-warning; system board

is under recommended temperature)

1.

Ambient temperature must be within normal operating
specifications

; see “Features and specifications” on page 4.

System over temperature for CPU "X"

(level-warning; CPU "X" reporting over
temperature condition)

1.

Ensure system is being properly cooled; see “Temperature
checkout” on page 26.

System under recommended CPU "X"
temperature

(level-warning; system

reporting under temperature condition for
CPU "X")

1.

Ambient temperature must be within normal operating
specifications

; see “Features and specifications” on page 4.

Message

Action

Fan "X" failure

(level-critical; fan "X"

had a failure)

1.

Check connections to fan "X"

2.

Replace fan "X"

Fan "X" fault

(level-critical; fan "X"

beyond recommended RPM range)

1.

Check connections to fan "X"

2.

Replace fan "X"

Fan "X" Outside Recommended Speed
Action

1.

Replace Fan "X"

Message

Action

System shutoff due to "X" current over
max value

(level-critical; system

drawing too much current on voltage "X"
bus)

1.

See “Power checkout” on page 24.

System shutoff due to "X" current under
min. value

(level-critical;

current on voltage bus "X" under minimum
value)

1.

See “Power checkout” on page 24.

Message