Vr-n100u users manual, Cn22: software reset, Bios – JVC VR-N100U User Manual

Page 82: Adaptec scsi bios

Advertising
background image

VR-N100U

USERS

MANUAL

Page 82 of 98

All Items Are Subject To Change Without Notice

Feb. 2004 Rev 1.0

6.2.6. CN22: Software Reset

Pin

Signal

1 Reset

2 GND

The software reset is a means to manually reset the appliance temporarily back to manufacturer’s default settings.

NOTE: VR-N100U rackmount systems do not utilize the manual software reset option.


6.3. BIOS

The settings for the customized Phoenix-Award BIOS for the industrial server board have been optimized for the VR-N100U
security application. No changes to the CMOS are required.

6.4.

Adaptec SCSI BIOS

The onboard Adaptec SCSI BIOS settings for the server board have been for the VR-N100U security application. No changes
to the Adaptec SCSI BIOS are required. The default settings are:

Adaptec Settings

Defaults

SCSI Controller ID

7

SCSI Controller Parity

Enabled

SCSI Controller Termination

Enabled

Sync Transfer Rate (SCSI ID #0~15)

160 MB/Sec

Initiate Wide Negotiation

Yes

Enable Disconnection

Yes

Send Start Unit Command

Yes

BIOS Multiple LUN Support

No

Include in BIOS Scan

Yes

Reset SCSI Bus at IC Initialization

Enable

Display <Ctrl><A> Message During BIOS Initialization

Enable

Extended Init 13 Translation for DOS Drives > 1 GByte

Enable

POST Display Mode

Verbose

SCSI Controller Int 13 Support

Enabled

Domain Validation

Enabled

Support Removable Disks Under Int 13 as Fixed

Disabled


Advertising