1. Registering the In Point, Out Point, and Chapter Marks

The following two methods can be used to register the In Point, Out Point, and chapter marks.
● Recording of time codes corresponding to tape positions.

● Direct entry using a keyboard.
Registering chapter marks : In order to register chapter marks using the REMOTE CONTROL screen, it will first of all be necessary

to set CHAPTER CREATION from the RECORDER MENU (2/2) screen to MANUAL. If this parameter
is set to AUTO, chapter marks will be automatically setup at specific intervals. The current setting for
CHAPTER CREATION is indicated in this screen’s CHAPTER field.

Recording from tape positions

Direct keyboard entry

q Use the VCR Control Panel to start playback on the VCR.

Press the STILL (

w) button and pause VCR playback at the

position to be registered. If necessary, use frame advance,
and the like to set the exact position.

w Use the cursor buttons (t, 8, 7, and 6) to select the point

to be registered (i.e., the In Point or Out Point), and then
press the SET button.
* The selected point will be highlighted.

e Use the cursor buttons (t, 8, 7, and 6) to select TC SET

and press the SET button.
● The time code will be registered for the selected point.

● If both IN point and OUT point are not selected, the time

code will be registered as a chapter point.

● When a time code is registered for a chapter mark, the

chapter list will be sorted from the smallest time-code
values, and the newly registered point will be highlighted.

* Editing can only be performed when there is continuous

time code up to 5 seconds from IN POINT.

q Use the arrow keys (†, ©, ∞, and √) to select the point to

be registered (i.e., the In Point or Out Point), and then press
the Enter key.

w Select the TC INPUT button using the cursor keys and input

a time code (hours: minutes: seconds: frames) into the TC
input field using the keyboard.

e Press the Enter key.

● The time code will be registered for the selected point.

● If both IN point and OUT point are not selected, the time

code will be registered as a chapter point

● When a time code is registered for a chapter mark, the

chapter list will be sorted from the smallest time-code
values, and the newly registered point will be highlighted.

IN POINT

OUT POINT

TC INPUT

EXIT

REMOTE CONTROL SCREEN ( 9PIN MASTER )

1

:

4
7

h

:

m

:

s

f

2

:

5
8

3
6
9

h

:

m

:

s

f

:

h

:

m

:

s

f

CHAPTER

MANUAL

BITRATE

8.0 Mbps

DISC REMAIN

000 min

:

:

:

EDL LOAD
EDIT/END

TC SET

TC CANCEL

ADJ

FINALIZE

00:00:00:00

00:00:00:00
00:25:00:00
00:40:00:00

00:15:00:00
00:30:00:00
00:45:00:00

00:20:00:00
00:35:00:00
00:50:00:00

00:10:00:00

IN POINT

OUT POINT

TC INPUT

EXIT

REMOTE CONTROL SCREEN ( 9PIN MASTER )

1

:

4
7

h

:

m

:

s

f

2

:

5
8

3
6
9

h

:

m

:

s

f

:

h

:

m

:

s

f

CHAPTER

MANUAL

BITRATE

8.0 Mbps

DISC REMAIN

000 min

:

:

:

EDL LOAD
EDIT/END

TC SET

TC CANCEL

ADJ

FINALIZE

00:00:00:00

00:00:00:00
00:25:00:00
00:40:00:00

00:15:00:00
00:30:00:00
00:45:00:00

00:20:00:00
00:35:00:00
00:50:00:00

00:10:00:00

q

w

e

q

w

w

IN POINT

OUT POINT

TC INPUT

EXIT

REMOTE CONTROL SCREEN ( 9PIN MASTER )

1

:

4
7

h

:

m

:

s

f

2

:

5
8

3
6
9

h

:

m

:

s

f

:

h

:

m

:

s

f

CHAPTER

MANUAL

BITRATE

8.0 Mbps

DISC REMAIN

000 min

:

:

:

EDL LOAD
EDIT/END

TC SET

TC CANCEL

ADJ

FINALIZE

00:00:00:00

00:00:00:00
00:25:00:00
00:40:00:00

00:15:00:00
00:30:00:00
00:45:00:00

00:20:00:00
00:35:00:00
00:50:00:00

00:10:00:00

EDL LOAD

Note

The framing mode will be matched to that used for time
codes on the connected device. When in the drop frame
mode, a value corrected automatically will be registered
when inputting the frame to drop. (U-model only)

Saving & Loading Time-Code Settings

Once settings have been made, they can be saved in your BD-X200’s internal memory. Even if
a different screen is opened or the power is turned off, stored data can then be loaded by
selecting EDL LOAD from the REMOTE CONTROL screen and pressing the Set button.
● If CHAPTER CREATION from the RECORDER MENU (2/2) screen is set to AUTO, it will not

be possible to select EDL LOAD on the REMOTE CONTROL screen.

● Whenever an external edit list (EDL) is read or time-code registration is started without

performing EDL LOAD, the settings will be updated accordingly. As a result, even if EDL
LOAD is selected in such a case, the previous data will not be reloaded.

Refer to page 68 for more details regarding the loading of external EDL.

62

q

Synchronous Recording

Recording Playback Signals From a VCR with RS-422A (continued)

2. Deleting the In Point, Out Point, and Chapter Marks

q Use the cursor buttons (t, 8, 7, and 6) to select the point to

be deleted (i.e., In Point, Out Point, or a chapter mark from the
chapter list), and then press the SET button.

w Use the cursor buttons (t, 8, 7, and 6) to select TC CANCEL

and press the SET button.
● The selected point (i.e., the In Point, Out Point, or a chapter

mark from the chapter list) will be deleted.

● Whenever a chapter mark is deleted, the chapter list will be

resorted.

IN POINT

OUT POINT

TC INPUT

EXIT

REMOTE CONTROL SCREEN ( 9PIN MASTER )

1

:

4
7

h

:

m

:

s

f

2

:

5
8

3
6
9

h

:

m

:

s

f

:

h

:

m

:

s

f

CHAPTER

MANUAL

BITRATE

8.0 Mbps

DISC REMAIN

000 min

:

:

:

EDL LOAD
EDIT/END

TC SET

TC CANCEL

ADJ

FINALIZE

00:00:00:00

00:00:00:00
00:25:00:00
00:40:00:00

00:15:00:00
00:30:00:00
00:45:00:00

00:20:00:00
00:35:00:00
00:50:00:00

00:10:00:00

w

IN POINT

OUT POINT

TC INPUT

EXIT

REMOTE CONTROL SCREEN ( 9PIN MASTER )

1

:

4
7

h

:

m

:

s

f

2

:

5
8

3
6
9

h

:

m

:

s

f

:

h

:

m

:

s

f

CHAPTER

MANUAL

BITRATE

8.0 Mbps

DISC REMAIN

000 min

:

:

:

EDL LOAD
EDIT/END

TC SET

TC CANCEL

ADJ

FINALIZE

00:00:00:00

00:00:00:00
00:25:00:00
00:40:00:00

00:15:00:00
00:30:00:00
00:45:00:00

00:20:00:00
00:35:00:00
00:50:00:00

00:10:00:00

EDIT/END

IN POINT

OUT POINT

TC INPUT

EXIT

REMOTE CONTROL SCREEN ( 9PIN MASTER )

1

:

4
7

h

:

m

:

s

f

2

:

5
8

3
6
9

h

:

m

:

s

f

:

h

:

m

:

s

f

CHAPTER

MANUAL

BITRATE

8.0 Mbps

DISC REMAIN

000 min

:

:

:

EDL LOAD
EDIT/END

TC SET

TC CANCEL

ADJ

FINALIZE

00:00:00:00

00:00:00:00
00:25:00:00
00:40:00:00

00:15:00:00
00:30:00:00
00:45:00:00

00:20:00:00
00:35:00:00
00:50:00:00

00:10:00:00

ADJUST

FINALIZE

3. Starting the Record Process

q Select EDIT/END from the REMOTE CONTROL screen and

press the SET button.
● VCR will begin playback by returning to the position 5 seconds

before the IN POINT.

● The unit will start record when the VCR reaches the IN POINT.

Recording of video and audio from the VCR to the DVD will be
carried out from the In Point to the Out Point with chapters
being created as specified.

w When playback reaches the Out Point, title recording will end

automatically.
● The VCR will automatically adopt STOP mode at this time.

● The DVD recorder will return to Stop mode and will end title

recording.

Ⅵ If another title is to be recorded, repeat operations from the

registration of the In Point and Out Point.

Setting the Optimum Bit Rate

ADJUST can be used to set the optimum bit rate (i.e., the amount of data per
second) for the remaining space on a disc based on the recording time (or duration)
between the In Point and the Out Point.
● DISC REMAIN displays an estimate of the available space for recording on the

current disc.

● BIT RATE displays the current bit-rate setting.

To set the bit rate that best suits the remaining disc capacity, select ADJUST and
then press the SET button.

4. Ending the Record Process

Ⅵ If you intend to play the recorded disc on this DVD recorder or on another player, select FINALIZE and press the SET button.

Once finalizing has been carried out, no addition recordings can be made on the disc.

Ⅵ To remove the recorded disc from your BD-X200, press the OPEN/CLOSE button on the front panel.

Notes

● Editing accuracy is ±5 frames.

● If no In Point has been registered, recording will begin at the current tape position. However, the tape must be positioned

before the Out Point and all chapter marks for this to be possible.

● If no Out Point has been registered, a manual stop must be carried out to end recording. Select EDIT/END to end the editing

process.

● When the chapter auto-create function is used, chapters will be created at specific intervals.

Advertising