Recording initializing, Troubleshooting (cont.), Attention – JVC DR-M10S User Manual

Page 110: Symptom possible cause corrective action

Advertising
background image

Filename [DR-M10SE_11Subsidiary.fm]

Masterpage:Left+

110

EN

Page 110

February 12, 2004 5:31 pm

TROUBLESHOOTING (cont.)

RECORDING

INITIALIZING

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

1. The desired programme cannot be

recorded.

● The channel position does not

correspond to that in the receiving area.

Set the correct channel position for the
receiving broadcast. (

pg. 98)

2. Recording and editing cannot be

made.

● No disc or a disc not being compatible

with the unit is loaded.

Load a recordable disc on the unit.
(

pg. 5)

● The disc loaded is not formatted.

Format the disc. (

pg. 106)

● A finalised DVD-R disc is loaded.

Recording and editing cannot be made on
finalised discs. (

pg. 107) Load a

recordable disc on the unit.

● The disc is full or does not have enough

space for the programme to be recorded.

Clear unnecessary programmes on the
disc or load a blank disc. (

pg. 69)

3. Timer programming cannot be made.

● Date and time is not correct.

Set date and time correctly. (

pg. 104)

4. Timer programming recording does not

start.

● Power failure occurred before the timer

programmed recording starts.

Check the timer programming. (

pg. 61)

5. S

HOW

V

IEW

Timer Programming cannot

be made.

● Date and time set on the unit is not

correct.

Set date and time correctly. (

pg. 104)

● The channel position does not

correspond to that in the receiving area.

Set the correct channel position for the
receiving broadcast. (

pg. 98)

6. Automatic Satellite Programming

recording does not start.

● The satellite receiver is not connected

properly to this unit.

Connect the satellite receiver to the L-2
IN/DECODER connector properly.
(

pg. 88)

7. On the front display panel, “– –:– –”

appears.

● Power failure occurred.

Set date and time correctly. (

pg. 104)

8. “PROGRAM FULL” appears on the TV

screen during timer programming.

● Eight programmes have already been

timer programmed.

Clear unnecessary programmes on the
unit, then try timer programming again.
(

pg. 61)

9. The disc space does not increase when

recorded programmes are cleared.

● The PC’s data recorded on a DVD-RAM

drive cannot be cleared on this unit.

Format the disc. (When the disc is soiled,
wipe the disc with a soft dry cloth before
formatting.) (

pg. 9, 106)

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

1. Malfunction occurs on the unit.

Press 1 to turn off the unit, press and
hold 1, then press 8 for two seconds or
more.

ATTENTION:

This unit contains microcomputers. External electronic noise or interference could cause malfunctioning. In such cases, switch the
unit off and unplug the mains power cord. Then plug it in again and turn the unit on. Take out the disc. After checking the disc,
operate the unit as usual.