Connecting and Configuring an EX Series Switch (CLI Procedure)

There are two ways to connect and configure an EX Series switch: one method is through
the console using the CLI and the other is using the J-Web interface. This topic describes
the CLI procedure.

NOTE: To run the

ezsetup

script, the switch must have the factory default

configuration as the active configuration. If you have configured anything on
the switch and want to run

ezsetup

, revert to the factory default configuration.

See Reverting to the Default Factory Configuration for the EX Series Switch.

Before you begin connecting and configuring an EX Series switch through the console
using the CLI:

Set the following parameter values in the console server or PC:

Baud Rate—9600

Flow Control—None

Data—8

Parity—None

Stop Bits—1

DCD State—Disregard

To connect and configure the switch from the console:

1.

Connect the console port to a laptop or PC using the RJ-45 to DB-9 serial port adapter.
The RJ-45 cable and RJ-45 to DB-9 serial port adapter are supplied with the switch.

EX2200, EX3200, or EX4200 switch—The console port is located on the rear panel
of the switch.

EX4500 switch—The console port is located on the front panel of the switch.

EX8200 switch—The console port is located on the Switch Fabric and Routing
Engine (SRE) module in slot SRE0 in an EX8208 switch or on the Routing Engine
(RE) module in slot RE0 in an EX8216 switch.

2.

At the Junos OS shell prompt

root%

, type

ezsetup

.

3.

Enter the hostname. This is optional.

4.

Enter the root password you plan to use for this device. You are prompted to re-enter
the root password.

5.

Enter

yes

to enable services like Telnet and SSH. By default, Telnet is not enabled and

SSH is enabled.