Mounting an ex2200 switch – Juniper Networks EX2200 User Manual

Page 73

Advertising
background image

Table 22: Inventory of Components Provided with an EX2200 Switch (continued)

Quantity

Component

8

Mounting screws

4

Rubber feet

1

RJ-45 cable and RJ-45 to DB-9 serial port adapter

Related

Documentation

Mounting an EX2200 Switch on page 53

Installing and Connecting an EX2200 Switch on page 51

Connecting and Configuring an EX Series Switch (CLI Procedure) on page 87

Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 89

Mounting an EX2200 Switch

You can mount the switch:

On two posts in a 19-in. rack or cabinet by using the mounting brackets provided with
the switch.

On four posts in a 19-in. rack or cabinet by using the separately orderable four-post
rack-mount kit.

In a position recessed 2 in. from the front of a 19-in. rack or cabinet by using the
2-in.-recess front brackets in the separately orderable four-post rack-mount kit. You
can mount the switch in this recessed position on two-post or four-post racks and
cabinets.

On a desk or other level surface by using rubber feet. The switch is shipped with four
rubber feet to be used to stabilize the chassis on a desk or other level surface.

On a wall by using the separately orderable wall-mount kit.

WARNING:

When mounting an EX2200 switch chassis in a vertical position, orient
the front panel of the chassis downward to ensure proper airflow and
meet safety requirements in the event of a fire.

When wall mounting Power over Ethernet (PoE) models (EX2200-24P
and EX2200-48P), install the wall-mount baffle above the units to reduce
the risk of objects or substances falling into the air exhaust or power
supply, which could cause a fire.

The holes in the mounting brackets are placed at 1 U (1.75 in. or 4.45 cm.) apart so that
the switch can be mounted in any rack or cabinet that provides holes spaced at that
distance.

53

Copyright © 2010, Juniper Networks, Inc.

Chapter 8: Installing the Switch