System specifications, System capacity, Specifications – Johnson Controls IFC-640 User Manual

Page 9: Temperature and humidity ranges, Agency listings and approvals, Standards

Advertising
background image

System Capacity

Intelligent Signaling Line Circuits ............1 expandable to 2

Intelligent detectors ......................................... 159 per loop

Addressable monitor/control modules .............. 159 per loop

Programmable internal hardware and output circuits
(4 standard) ...................................................................... 68

Programmable software zones ......................................... 99

Special programming zones ............................................. 14

LCD annunciators per

CPU-640/-640E

and JNCA

(observe power)................................................................ 32

ACS annunciators per

CPU-640/-640E

.........................................................32 address x 64 points

ACS annunciators per JNCA

................................................32 address x 64 or 96 points

NOTE: The

JNCA

supports up to 96 annunciator address points

per ACM-24/48.

Specifications

Primary input power,

JCPU-640

board: 120 VAC, 50/60 Hz,

3.0 amps.

JCPU-640

E board: 220/240 VAC, 50/60 Hz, 1.5

Amps.

Total output 24 V power: 6.0 A in alarm.

NOTE: The power supply has a total of 6.0 Amps of available
power. This is shared by all internal modules.

Standard notification circuits (4): 2.5 A each.

Four-wire detector power: 1.25 A.

Non-resettable regulated power outputs: 1.25 A each.

Battery charger range: 12 AH – 55 AH. Use separate cabi-
net for batteries over 25 AH.

Optional high-capacity (25 – 120 AH) battery charger:
CHG-120 (see CHG-120 data sheet, DN-6040).

Float rate: 27.6 V.

Temperature and Humidity Ranges

This system meets NFPA requirements for operation at 0 –
49ºC/32 – 120ºF and at a relative humidity 93% ± 2% RH

(noncondensing) at 32ºC ± 2ºC (90ºF ± 3ºF). However, the
useful life of the system's standby batteries and the electronic
components may be adversely affected by extreme tempera-
ture ranges and humidity. Therefore, it is recommended that
this system and its peripherals be installed in an environment
with a normal room temperature of 15 – 27ºC/60 – 80ºF.

Agency Listings and Approvals

The listings and approvals below apply to the basic IFC-640
control panel. In some cases, certain modules may not be listed
by certain approval agencies, or listing may be in process. Con-
sult factory for latest listing status.

UL: S1570

ULC: ML118

FM APPROVED Exceptions – JCPU-640E, Proprietary

service

CSFM: 7165-0554:143, 7170-0554:142

MEA: 317-01-E Vol. II

City of Chicago

Standards

The IFC-640 complies with the following UL Standards and
NFPA 72 Fire Alarm Systems requirements :

– UL 864 (Fire)

– UL 1076 (Burglary)

– LOCAL (Automatic, Manual, Waterflow and Sprinkler

Supervisory).

– AUXILIARY (Automatic, Manual and Waterflow) (requires

4XTMF).

– REMOTE STATION (Automatic, Manual and Waterflow)

(requires 4XTMF).

– PROPRIETARY (Automatic, Manual and Waterflow).

Not applicable for FM.

– EMERGENCY VOICE/ALARM.

Page 9 of 9 — JCI-6856:A • 12/01/06

AWACS™, HARSH™, NIS™, Notifier Integrated Systems™, and NO-
TI•FIRE•NET™ are all trademarks; and FlashScan®, NION®, NOTIFIER®,
ONYX®, UniNet®, VeriFire®, and VIEW® are all registered trademarks of
Honeywell International Inc.
©2006 by Johnson Controls Inc. All rights reserved. Unauthorized use of this
document is strictly prohibited.

This document is not intended to be used for installation purposes.

We try to keep our product information up-to-date and accurate.

We cannot cover all specific applications or anticipate all requirements.

All specifications are subject to change without notice.

For more information, contact Johnson Controls Field Support Center.

507 East Michigan Street, Milwaukee, WI 53202 www.johnsoncontrols.com

Made in the U.S. A.

SYSTEM SPECIFICATIONS

Advertising