Building in – John Lewis JLBIOS662 User Manual

Page 33

Advertising
background image

For Europe use only

Min. size Cable/

flex

Cable/flex type

Fuse

1,5 mm²

H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90),
H05 BB-F

13 A

Building In

Warning! The oven must be installed
by qualified and competent personnel
to the relevant National Standards and
according to the instructions supplied
in "Electrical connections" and
"Installation" chapters.

Please ensure that when the oven is
installed it is easily accessible for the
engineer in the event of a breakdown.

Building In

The surround or cabinet into which the oven
will be built must comply with these
specifications:
• the dimensions must be as shown in the

relevant diagrams;

• the materials must withstand a

temperature increase of at least 60°C
above ambient;

• proper arrangements must be made of a

continuous supply of air to the oven to
prevent the oven overheating.

Dimensions of the oven and recess required
are given in the relevant diagrams.

594

2

20

570

590

540

560

50

580

550 min

560÷570

550 min

593

560-570

80ч100

33