Troubleshooting Chart

1.

Control is on and appears to
be functioning, but no steam.

A. Allow 2 minutes for steam to

flow.

B. Replace water filter, drain and

flush out steamer and steam
plumbing. Pour six ounces of
water into the steam delivery
tube. Reset high limit safety
switch.

A. Replace water filter, drain and

flush out steamer and steam
plumbing. Pour six ounces of
water into the steam delivery
tube. Reset high limit safety
switch.

A. Replace water filter, drain and

flush out steamer and steam
plumbing. Pour six ounces of
water into the steam delivery
tube.

2.

Steam generator will fill
and produce steam, but will
boil water away without
refilling and shut itself off.

3.

Excess water is exhausted
from the steam head.

A. Steamer heating up.

B. High limit safety switch tripped.

A. There is a high concentration of

mineral buildup in the tank
water because of continued use
without draining the tank. This
causes faulty water fill opera-
tion, and the high temperature
safety switch will trip.

A. There is a high concentration of

mineral buildup in the tank.

PROBABLE CAUSE

PROBLEM

REMEDY

30