CHAPTER 6
Powering Up the System

6-2

Powering Up

This procedure assumes that the system is already connected to a DC
power source. See

Chapter 4, Cabling the ERX System

.

For specifications on the electrical requirements for the system, see

Appendix A, System Specifications

. For details on the power consumed

by the different ERX modules, see

Appendix B, Module Specifications

.

Branch Circuit Caution: Evaluate the overall loading of the branch circuit before
you install any equipment into a rack.

To power up the system:

1

Turn on the power switches located on the power input module in
the rear of the system. See

Figure 6-1

.

2

Monitor the LEDs on the front of the SRP modules to verify that the
system is booting properly. See

Table 8-2

in

Chapter 8,

Troubleshooting

.

When the prompt appears on the system console, the system is in
User Exec mode:

host1>

3

Enter the

enable command to access the Privileged Exec mode:

host1>enable

host1#

In Privileged Exec mode you can begin to configure the system. See
the

ERX System Basics Configuration Guide, Chapter 2, Command

Line Interface

for more information.

Connect DC power (–48 VDC) to the power input lugs on the
power input module.

Chapter 4, Cabling the
ERX System

Connect a management console to the system.

Chapter 5, Accessing
the ERX System

(Optional) Connect the 10/100Base-T port to the network.

Chapter 5, Accessing
the ERX System

Table 6-1 Installation tasks (continued)

Installation Task

Reference